CONTEXT PLUS XFP501E 1 LOOP 16 ZONE ADDRESSABLE FIRE ALARM PANEL
"Specifications: - Certified: EN54-2/4 (LPCB) - Protocol: C-TEC CAST - Mains: 230V AC, 50/60Hz, 350mA max - PSU: 27V DC nominal, 1.4A max @ 230V AC - Quiescent Current: 50mA (unloaded) - Battery: 2 x 12V 3.2Ah VRLA (series) - Loop Drivers: 1 - Max Loop Output: 500mA @ 40V - Loop Length: Up to 1km - Devices per Loop: Max 255 - Sounder Circuits: 2 (500m max each) - Sounder Output: 400mA max - EOL Resistor: 6.8kΩ, 0.25W - Relays: 3 x programmable, 1 x fault relay (1A @ 30V DC) - Aux Power: 24V DC (19.5–28V), 100mA max - Inputs: 2 x programmable (0V trigger, 27V max) - PC Connection: RS232 (via XFP507 kit), no printer - Display: 2x40 backlit LCD, 16 zonal LEDs + system indicators - Wiring: Max conductor size 1mm² - Networking: Optional RS485 (XFP761), up to 8 panels/repeaters, 1km/500m max - Size: 380 x 235 x 96mm - Material: Plastic (RAL7035 textured) - IP Rating: IP30 - Weight: 1.8kg (excl. batteries) - Operating Temp: -5°C to +40°C, RH 95% max - Price mentioned per piece"
Read full descriptionSKU: GEN-FIR-00275
Description
The XFP501E / X / CON is an addressable fire alarm control panel with one loop supporting up to 16 zones / 16 addressable devices (or more devices per zone depending on device grouping). It supports the XP95 / Discovery protocol in the “X” variant and also a CAST protocol variant (“E / CON”) depending on model. It comes in a plastic enclosure, includes a keypad with key switch entry, and is LPCB certified to EN54-2 / EN54-4.
This panel is often chosen for small to medium installations where a full two-loop panel isn’t necessary. It supports networking (RS485) for expansion and offers conventional sounder circuits, programmable inputs & relays, and features such as “auto address / loop learn.”
Key Features
• Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
• Compatibility with Context Plus addressable detectors and devices.
• Two independently programmable conventional sounder circuits.
• Two programmable inputs.
• A fault output relay and three programmable relay outputs with voltage free changeover contacts.
• A selection of zone dependency/coincidence functions.
• A day/night (building occupied/unoccupied) function.
• An investigation delay period function.
• Phased evacuation facility.
• An alarm counter that records how many times the panel has been in alarm state.
• Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
• An integral EN54-4/A2 switch mode power supply.
• Adjustable contamination levels.
• Earth fault monitoring.
• Combined keypad / key switch entry to Access Levels 2 and 3.
• 999 event monitoring.
• An intuitive Windows based upload-download PC program.
• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
Industrial Uses / Applications
Small to medium commercial buildings (offices, shops)
Schools, clinics, small hospitals
Single building installations with moderate fire detection needs
Retail premises, warehouses with limited zones
Projects where future expansion (networking) might be needed"